In this article, we share the Basic Electrical and Electronics Engineering BEE 312302 MSBTE K Scheme Manual Answer.

These manual practicals are based on the new syllabus of MSBTE for second-semester engineering diploma students.
BEE 312302 MSBTE K Scheme Manual Answer
- Practical No.1: Measure the parameters of a simple electrical circuit and identify the presence of flux lines in the magnetic circuit. (E.g., current, voltage, power, flux).
- Practical No. 2: Measure frequency, Time period, Peak value, RMS value of sinusoidal AC waveform for resistive and inductive circuit using CRO.
- Practical No. 3: Phase difference between voltage and current in inductive circuit.
- Practical No. 4: Measure the live voltage, phase voltage and phase current and line current in three phase star connected balanced load.
- Practical No. 5: Measure the live voltage, phase voltage and phase current and line current in three phase delta connected balanced load.
- Practical No. 6: Determination of the voltage ratio and current ratio of single phase transformer. I Practical Significance:
- Practical No. 7: Operate DC Shunt motor by connecting three point starter.
- Practical No. 8: Operate DC series motor by connecting two point starter.
- Practical No. 9: Reverse the direction of rotation of universal motor.
- Practical No. 10: Demonstrate the operation of stepper motor for various speed rotation.
- Practical No. 11: Use of Multimeter for measurement of voltage, current (AC, DC), resistance and continuity of the given electrical circuit.
- Practical No. 12: Connect the fuse in electrical circuit and check its operation at normal and abnormal conditions.
- Practical No. 13: Connect MCB in electrical circuit and check its operation at normal and abnormal conditions.
- Practical No. 14: Connect ELCB in electrical circuit breaker and check its operation at normal and abnormal conditions.
- Practical No.15 Use of earth tester for measurement of earthing resistance of a installed earthing of laboratory.
- Practical No.16 : Connect the Zener diode in the circuit and test its operation in forward and reverse bias mode.
- Practical No.17: Determine the voltage regulation by using zener diode under variable input and output conditions.
- Practical No.18: Check the output waveform of L, C and π filters on CRO of rectifier circuit.
- Practical No.19: Make the input and output connections of UPS and measure the output voltage under online and offline mode.
- Practical No.20: Make the input and output connections and check the operation of UPS under normal and overload condition.
- Practical No.21: Test input/output characteristics of NPN transistor in CE Configuration.
- Practical No.22: Test input/output characteristics of NPN Transistor in CB Configuration.
- Practical No.23: Check the switch ON and switch OFF condition of LED by using transistor.
- Practical No.24: Determine the drain and transfer characteristics of FET.
- Practical No.25: Measure temperature of liquid using RTD (PT-100) transducer.
- Practical No.26: Measure temperature of liquid using thermocouple.
- Practical No.27: Check the motion of given object using photoelectric sensor.
- Practical No.28: Measure the resistance of LDR in varying light intensity.
- Practical No.29: Measure displacement using LVDT.
- Practical No.30: Measurement of displacement using potentiometer.